EKCO DUMMY LOAD AND
ABSORPTION WATTMETER

TYPE M2249 & TYPE C39242

The M2249 Dummy Load permits a radar system to be bench tested without radiating. It can be used with any 3 cm. system provided RF mean power does not exceed 25W and peak power does not exceed 100 kW. The dummy load has a directive feed attenuator which can be connected to a C39242 Absorption Wattmeter. A matched load is fitted to the output flange of the directive feed and must be removed in order to connect the wattmeter.

The C39242 Absorption Wattmeter enables a comparative measurement of transmitter power output to be made by noting the height of a glowing neon column in a tube having an arbitrary calibration of 2 to 9 centimetres and comparing it with readings taken at other times with the same wattmeter.

Text and Photograph reproduced from Ekco Electronics Catologue supplied by Chris Poole